{"id":2071,"date":"2025-07-23T16:03:03","date_gmt":"2025-07-23T08:03:03","guid":{"rendered":"https:\/\/pumpingchem.com\/?page_id=2071"},"modified":"2025-09-22T10:41:03","modified_gmt":"2025-09-22T02:41:03","slug":"dj-powder-transfer-pumps-2","status":"publish","type":"page","link":"https:\/\/pumpingchem.com\/ru\/dj-powder-transfer-pumps-2\/","title":{"rendered":"DJ Powder Transfer Pumps"},"content":{"rendered":"\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-df6fcc99b3eac9c6c4517167ffa4786d\" id=\"block-1d48f7da-4e0b-4b42-8087-326049596bb0\" style=\"font-style:normal;font-weight:900\">DJ Powder Transfer Pump \u2013 Transfer and convey your dry powders faster and cleaner<\/h3>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-group__inner-container\">\n<figure class=\"wp-block-image alignwide is-style-rounded\" id=\"block-706d0350-b585-445a-9914-d3d4d75ad3a9\"><img decoding=\"async\" src=\"https:\/\/pumpingchem.com\/wp-content\/uploads\/2025\/07\/image-2.png\" alt=\"This image has an empty alt attribute; its file name is image-2.png\"\/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\"><\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"block-2f2cbadf-d32c-42ad-8dd2-a4d139af45c8\"><strong>Application Conditions<\/strong><\/h3>\n\n\n\n<ul id=\"block-0ec31a2c-d5a0-4b79-9ba3-fdaf2b2200f9\">\n<li>Powder must be lightweight, dry, and non-caking.<\/li>\n\n\n\n<li>Particle size smaller than 75 \u03bcm (over 200 mesh).<\/li>\n\n\n\n<li>Bulk density less than 800 kg\/m\u00b3.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"block-68d26ded-4f6c-47f0-a27c-f89d1ac8a519\"><strong>Operating Requirements<\/strong><\/h3>\n\n\n\n<ul id=\"block-11ea17c4-a757-4367-951c-c180b1666913\">\n<li><strong>Fluidizing air pressure<\/strong>: Can be set from 1.0 to 5.5 bar depending on powder fluidity. (Controlled via a small regulator filter for the auxiliary gas in the liquid chamber.)<\/li>\n\n\n\n<li><strong>Working air pressure<\/strong>: Can be set from 1.5 to 6.0 bar depending on required transfer volume. (Controlled via a large regulator filter.)<\/li>\n\n\n\n<li><strong>Inlet<\/strong>: Maximum horizontal distance is 3\u20138 meters, depending on pump size.<\/li>\n\n\n\n<li><strong>Outlet<\/strong>: The smaller the bulk density, the higher the conveying height, up to a maximum of 30 meters (straight pipeline without bends).<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"block-ff4e21c4-dbc3-4b47-83ec-603c2f9e5fa0\"><strong>Features &amp; Advantages<\/strong><\/h3>\n\n\n\n<ul id=\"block-58bc5e9d-a34b-4dd6-9538-6728fb2977f8\">\n<li>Replaces manual powder handling<\/li>\n\n\n\n<li>Reduces air pollution \u2013 transfers powder directly from the container to where it is needed<\/li>\n\n\n\n<li>Unique air conveying system prevents powder clogging<\/li>\n\n\n\n<li>Economical and simple \u2013 no need for large complex systems<\/li>\n\n\n\n<li><strong>Leak-free<\/strong>: Excellent sealing ensures no powder leakage, preventing operator exposure<\/li>\n\n\n\n<li><strong>Low shear<\/strong>: Minimal material agitation to avoid heat generation<\/li>\n\n\n\n<li><strong>Portable<\/strong>: Can be quickly moved from one location to another<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>DJ Powder Transfer Pump \u2013 Transfer and convey your dry powders faster and cleaner Application Conditions Operating Requirements Features &amp; Advantages<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"translation":{"provider":"WPGlobus","version":"2.12.0","language":"ru","enabled_languages":["en","de","fr","nl","hi","ja","id","it","zh","ko","pt","ar","ru","es","th","tr","vi"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"de":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"nl":{"title":false,"content":false,"excerpt":false},"hi":{"title":false,"content":false,"excerpt":false},"ja":{"title":false,"content":false,"excerpt":false},"id":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"zh":{"title":false,"content":false,"excerpt":false},"ko":{"title":false,"content":false,"excerpt":false},"pt":{"title":false,"content":false,"excerpt":false},"ar":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"th":{"title":false,"content":false,"excerpt":false},"tr":{"title":false,"content":false,"excerpt":false},"vi":{"title":false,"content":false,"excerpt":false}}},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/pumpingchem.com\/ru\/wp-json\/wp\/v2\/pages\/2071"}],"collection":[{"href":"https:\/\/pumpingchem.com\/ru\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pumpingchem.com\/ru\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pumpingchem.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pumpingchem.com\/ru\/wp-json\/wp\/v2\/comments?post=2071"}],"version-history":[{"count":0,"href":"https:\/\/pumpingchem.com\/ru\/wp-json\/wp\/v2\/pages\/2071\/revisions"}],"wp:attachment":[{"href":"https:\/\/pumpingchem.com\/ru\/wp-json\/wp\/v2\/media?parent=2071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}